NIKLAS Safety One Safety tester for final testing

Safety One tests high voltage, insulation and protective conductor in one device and shows the affected measuring path in the event of a fault. Every attempt and every rework is stored under the serial number of the test item.

NIKLAS Safety One as a benchtop unit and as a 19-inch rack with touch display, connection panel, start and stop buttons

Four tests in one device

Safety One tests high voltage, insulation and protective conductor with shared operation and one test report for each serial number.

High voltage AC

Up to 5 kV and 100 mA

Dielectric strength test with AC voltage, around 500 VA at the maximum values.

High voltage DC

Up to 6 kV and 5 mA

Dielectric strength test with DC voltage, with monitored discharge and residual voltage monitoring.

Insulation

50 to 1,200 V DC, up to 10 GΩ

Insulation resistance with its own measuring module.

Protective conductor

2 to 32 A AC, four-wire measurement

Protective conductor resistance using four-wire technology. Sockets and cables are part of the measuring path.

Design: desk or 19-inch rack. Launch: 2027. Registering your interest is non-binding, and we will inform you before the launch.

Narrowing down faults directly at the test station

If a test fails, Safety One shows the affected measuring path and the matching connection diagram. Your team finds the cause in a targeted way and then repeats only this test step.

Checking the adapter before the start

Before the start, Safety One checks the adapter, test plan revision and calibration status. With the wrong adapter, the test does not start.

Recording rework completely

Failed attempt, action taken and repeat test are in the report under the same serial number.

Narrowing down affected test items

If an adapter fails or a calibration is invalid, Safety One shows which serial numbers are affected.

Reconnecting safely

Safety One only releases opening and reconnecting when there is no longer any dangerous residual voltage. For this, the device monitors the residual voltage.

Front view of NIKLAS Safety One with the test sequence on the display and connections for high voltage and protective conductor

Four working views from start to report

Operation follows the sequence at the test station. In each step, the large touch display shows only what your team needs at that moment.

NIKLAS Safety One as a benchtop unit with touch display, connection panel, start and stop buttons

Test

Assign the serial number and adapter, with the approved test plan revision and readiness at a glance.

Diagnostics

Finding, affected measuring path and permitted next step in one view.

Quality

All attempts, rework and repeat tests of a test item in one overview.

Service

Calibration, reference test, software updates and module replacement, documented for each device.

Does Safety One suit your test station?

Tell us your test items and test voltages. We tell you whether Safety One covers your final testing.

As a benchtop unit or in a 19-inch rack

Safety One is available in two designs with the same front and the same operation.

Desk for the test station

Benchtop unit for stationary test stations in final testing and rework. Housing approx. 449 × 496 × 266 mm (W × D × H).

Rack for the test bench

For installation in a 19-inch mounting in test benches and control cabinets, with handles on the front.

Front and operation

Large touch display, start, stop and emergency stop as well as a structured connection panel for high voltage and protective conductor.

Connections on the back

Safety connection, digital inputs and outputs, separate network connections for OT and IT, USB for service and scanner, warning lamp and mains connection with switch.

We are happy to clarify with you which design suits your test station.

Back of NIKLAS Safety One with safety connection, digital inputs and outputs, network, USB and mains connection

Test data stays in your network

Safety One does not need an internet connection. Test plans and results are stored locally on the device and go to your systems via documented interfaces.

Test plans with approval

Test plans are versioned and provided with roles and approvals. Only approved revisions start a test.

Report for each serial number

You export results, rework and repeat tests as CSV, JSON or PDF.

Connection to MES and ERP

You pass on results via the API and separate network connections. We supply a sample client and data model.

Safety One will be launched in 2027

If you register your interest in the device now, we will inform you about dates and equipment before the launch. Registering your interest is non-binding.

Frequently asked questions about NIKLAS Safety One

Here we answer what test station operators want to know about Safety One before registering their interest.

Which tests does NIKLAS Safety One carry out?

Safety One tests the dielectric strength with high voltage AC up to 5 kV and 100 mA and DC up to 6 kV and 5 mA. In addition, there is the insulation measurement with 50 to 1,200 V DC up to 10 GΩ and the protective conductor test with 2 to 32 A AC using four-wire technology.

When will Safety One be available?

Safety One will be launched in 2027. If you register your interest in the device now, we will inform you about dates and equipment before the launch.

What is the difference between the desk and the rack?

Both designs have the same front with display, start, stop and connection panel. The desk stands on the test station as a benchtop unit, while you install the rack in a 19-inch mounting in your test bench.

How do the test results get into our MES or ERP?

Safety One stores test plans and results locally and does not need an internet connection. You pass on results to MES or ERP via the API and the network connections. CSV, JSON and PDF are available for export.

Can Safety One be integrated into an existing test bench?

Yes. On the back there is a safety connection and digital inputs and outputs. You use them to connect the interlocking, emergency stop and sequence signals of your test bench.

How do service and calibration work?

The measuring equipment sits in an exchangeable measuring cassette. After an exchange, Safety One guides you through recommissioning. Calibration and reference test are clearly assigned to the device.

Register interest in Safety One for your test station

Tell us the test item, tests and quantity. We will get back to you before the launch with dates and equipment.

We process your details to handle your enquiry. See our privacy policy.

Simon Niklas, your contact

Simon Niklas

Mechanical engineer, M.Sc.

+49 941 56956720[email protected]

“Good engineering proves itself in day-to-day production. That is why we combine technical planning with a close understanding of process, operation and maintenance.”

Book a consultation